The short answer
- Add up the watt-hours per day your must-run devices use, not just their watts.
- Divide by about 0.75 to cover inverter and depth-of-discharge losses. That's the battery size for one day with no recharging.
- Check that the station's continuous and surge watts cover your biggest startup load.
- For multi-day outages, plan the recharge (solar or a generator) and keep the unit cool. Southeast heat is a real limit.
Why South Carolina outages need their own math
Most power station marketing pictures a weekend camping trip. A Carolina hurricane outage is different. According to the South Carolina State Climatology Office, Hurricane Helene left about 1,358,000 customers without power at its peak, more than Florida, Georgia or North Carolina. The state's Office of Regulatory Staff found that restoring all of them took roughly two weeks. Outages also hit in late summer and early fall, when it's hot and humid. Food spoils fast, and anything you store in a garage bakes.
That changes the question. It isn't "how long will this run my laptop?" It's "how do I keep the fridge cold, the phones charged and maybe a CPAP running for several days, in the heat?"
Step 1: List only what has to run
Write down the devices you can't do without. For most households that's a short list:
- Refrigerator and/or chest freezer
- Phones, a laptop and the internet router
- A few LED lights
- Fans (you're not running central AC on a portable station)
- Medical devices such as a CPAP or oxygen concentrator. Ask your provider about power needs and battery options.
Leave off anything that heats: space heaters, hair dryers, electric ranges, water heaters and dryers. They use huge amounts of energy, and they're what turns a "fridge for three days" plan into "fridge for eight hours."
Step 2: Find watts and daily watt-hours
Two different numbers matter:
- Watts (W) is how hard a device pulls at any moment. That decides whether the station's inverter can run it.
- Watt-hours (Wh) is how much energy it uses over time. That decides how long the battery lasts.
Where to find them:
- Refrigerators and freezers: the yellow EnergyGuide label lists estimated kWh per year. Divide by 365 to get kWh per day, then multiply by 1,000 for Wh. A fridge compressor cycles on and off, so its running watts alone will mislead you.
- Electronics: the power adapter label lists output volts and amps. Volts × amps gives the maximum watts. Multiply by the hours you'll run it.
- Lights and fans: the watts are printed on the bulb or the nameplate.
Step 3: Do the math (worked example)
Here's an example. The numbers are illustrations, so use your own labels:
| Device | How we got the number | Wh per day |
|---|---|---|
| Refrigerator | Label says 600 kWh/yr ÷ 365 | ≈ 1,644 |
| Internet router | Adapter 12 V × 1.5 A = 18 W max × 24 h | ≈ 432 |
| 3 LED bulbs | 3 × 9 W × 5 h | 135 |
| Phones and a laptop | Rough daily charging | ≈ 100 |
| Total | ≈ 2,311 Wh |
Step 4: Apply a realistic usable-capacity factor
A station rated at 1,000 Wh won't deliver 1,000 Wh to an AC appliance. Converting battery power to household AC loses energy, the battery management system holds some capacity in reserve, and the unit draws a little power just to stay on.
BLUETTI publishes its own runtime formula for the AC180: rated capacity × 90% depth of discharge × 85% inverter efficiency ÷ (load + about 15 W of self-consumption). That works out to roughly 75% of the rating before self-consumption. BLUETTI also notes the formula isn't suitable for compressor loads like refrigerators, which cycle and surge. Other brands use different numbers. For planning, 0.75 is a reasonable, conservative factor:
Battery Wh needed for 1 day ≈ daily Wh ÷ 0.75
Example: 2,311 ÷ 0.75 ≈ 3,081 Wh
So in this example, a ~1 kWh station covers about 8–9 hours of the full list (the list averages about 96 W), while a ~4 kWh unit covers a little over a day. Neither lasts through a two-week outage without recharging.
Step 5: Check continuous watts and surge
Capacity is only half the decision. The inverter has to handle the moment a compressor or motor kicks on. Compare your largest startup load against the station's surge rating, and your total running load against its continuous rating. Here's how current models compare on paper:
| Class | Example (manufacturer specs) | Capacity | Continuous / surge | Fits this example for… |
|---|---|---|---|---|
| ~1 kWh | BLUETTI AC180 | 1,152 Wh | 1,800 W / 2,700 W | ~9 hours |
| ~1 kWh | EcoFlow DELTA 3 | 1,024 Wh (expandable to 5 kWh) | 1,800 W / 3,600 W | ~8 hours; more with extra batteries |
| ~1.5 kWh | Goal Zero Yeti 1500 (6th Gen) | 1,505 Wh | 2,000 W / 3,600 W | ~12 hours |
| ~4 kWh | Goal Zero Yeti PRO 4000 | 3,994 Wh | 3,600 W / 7,200 W | ~31 hours |
| ~4 kWh+ | EcoFlow DELTA Pro 3 | 4,096 Wh (expandable to 12 kWh per unit) | 4,000 W (120/240 V) / 8,000 W | ~32 hours; 240 V loads possible |
Step 6: Plan the recharge, and the heat
For a multi-day outage, the real question is how fast you can put energy back in:
- Solar input limit. The station caps solar input no matter how many panels you buy (500 W on the AC180 and DELTA 3, 900 W on the Yeti 1500, 2,600 W across two inputs on the DELTA Pro 3). Panels produce well below their rating in haze, heat and at low sun angles. Manufacturer charge times assume ideal conditions.
- Generator charging. Many stations accept AC from a generator. Running a small generator for a couple of hours to refill the battery, then shutting it off, can save fuel and noise. Follow every generator safety rule.
- Temperature limits. This is the one Carolina buyers miss. BLUETTI lists AC180 charging at 32–104°F and limits output to 1,500 W between 86°F and 104°F. A closed garage in August can go past that. Keep the station in the coolest conditioned room you have, and don't charge it in a parked car.
Stretch what you have
- Keep the fridge and freezer closed. Ready.gov says a closed refrigerator keeps food cold for about 4 hours and a full freezer holds its temperature for about 48 hours.
- Run the fridge in blocks (for example, a few hours on, a few off) and check it with a thermometer. Throw out food that's been above 40°F for two hours or more.
- Charge phones from the station's USB ports instead of AC adapters. You skip a conversion step and waste less energy.
Choosing a size
- ~1 kWh: phones, router, lights, a CPAP and part-time fridge use. Easy to carry. A good first step.
- ~1.5–2 kWh: more comfortable fridge coverage with solar top-ups.
- ~4 kWh and expandable: a full day or more of essentials, possible 240 V circuits, and options to connect to a home panel through a transfer device installed by an electrician. See whole-home battery basics.
Ready to compare specific units? Our solar generator comparison lines up current models on published specs.
Check current price at BLUETTI Check current price at EcoFlow Check current price at Goal ZeroFrequently asked questions
Will a 1,000 Wh power station run my refrigerator?
Usually for part of a day, not for days. Divide your fridge's yearly kWh (from its yellow EnergyGuide label) by 365 to get daily use, then compare it with about 75% of the station's rated capacity. A fridge using 1.6 kWh a day would drain a 1 kWh station in well under a day unless you recharge it.
Can a portable power station run a well pump?
Many well pumps run on 240 volts and draw a large startup surge. Most 1–1.5 kWh stations only put out 120 volts. A unit with 240V output (for example the EcoFlow DELTA Pro 3) or a generator may be needed. Check the pump's nameplate and have an electrician confirm how it would connect.
Can I charge a power station in a hot garage in July?
Check the manual. Many stations stop charging above about 104°F, and some cut their output at high temperatures. BLUETTI, for example, limits the AC180 to 1,500 W when it's discharging between 86°F and 104°F. Keep the unit in the coolest conditioned room you have.
How many solar panels do I need to recharge during an outage?
Start from your daily watt-hours and your station's maximum solar input. Real-world output is well below the panel rating, so plan for several hours of strong sun at partial output. Manufacturer charge-time charts assume ideal sun, so treat them as best case.
Sources
Specs and figures come from these pages, checked November 16, 2026. Manufacturers update products and prices often; confirm on the official page before you buy.
- SC State Climatology Office: Tropical Cyclone Helene report (peak outages)
- SC Office of Regulatory Staff: Helene energy resilience assessment (restoration time)
- BLUETTI AC180 product page and FAQ (runtime formula, temperature limits)
- EcoFlow DELTA 3 product page (specs)
- EcoFlow DELTA Pro 3 product page (specs)
- Goal Zero Yeti 1500 (6th Gen) product page
- Goal Zero Yeti PRO 4000 product page
- Ready.gov: Power outages (food safety timing)